User contributions for Oluschinski
Appearance
Results for Oluschinski talk block log uploads logs
A user with 1,863 edits. Account created on 4 July 2025.
7 September 2026
- 12:4012:40, 7 September 2026 diff hist 0 N File:SE-Probes Fig2.jpg No edit summary current
- 12:4012:40, 7 September 2026 diff hist 0 N File:SE-Probes Fig1.jpg No edit summary current
- 12:4012:40, 7 September 2026 diff hist +6,881 N Ultrasonic Transmitter(S)-Receiver(E) Sensors Created page with "{{Language_sel|LANG=ger|ARTIKEL=Ultraschall-Sende(S)-Empfänger(E)-Prüfköpfe}} {{PSM_Infobox}} <span style="font-size:1.2em;font-weight:bold;">Ultrasonic transmitter(S)-receiver(E) sensors</span> __FORCETOC__ ==General information== Ultrasonic S/E sensors, also known as transmitter/receiver sensors, consist of a transmitter unit and a receiver unit that are electrically and vibrationally separated, i.e. separate Piezoelectric Ceramic Transducer|piezoelectric transd..." current
- 12:3912:39, 7 September 2026 diff hist +143 Ultrasonic Transmission Technique No edit summary current
- 12:3912:39, 7 September 2026 diff hist 0 N File:TOFD-2.jpg No edit summary current
- 12:3912:39, 7 September 2026 diff hist 0 N File:TOFD-Fig1.jpg No edit summary current
- 12:3812:38, 7 September 2026 diff hist +6,326 N Ultrasonic Time-of-Flight Diffraction (TOFD) Technique Created page with "{{Language_sel|LANG=ger|ARTIKEL=Ultraschall-Laufzeit-Beugungsverfahren (TOFD)}} {{PSM_Infobox}} <span style="font-size:1.2em;font-weight:bold;">Ultrasonic time-of-diffraction (TOFD) technique</span> __FORCETOC__ ==General== The time-of-flight diffraction (TOFD) method is an ultrasonic measurement method used in particular to test steel components for cracks and volume defects. It is used for quality control of Ultrasonic Weld Inspecti..." current
- 12:3812:38, 7 September 2026 diff hist 0 N File:US Standard Sensors-Fig6.jpg No edit summary current
- 12:3812:38, 7 September 2026 diff hist 0 N File:US Standard Sensors-Fig5.jpg No edit summary current
- 12:3812:38, 7 September 2026 diff hist 0 N File:US Standard Sensors-Fig4.jpg No edit summary current
- 12:3712:37, 7 September 2026 diff hist 0 N File:US Standard Sensors-Fig3.jpg No edit summary current
- 12:3712:37, 7 September 2026 diff hist 0 N File:Normalpruefkoepfe-2.JPG No edit summary current
- 12:3712:37, 7 September 2026 diff hist 0 N File:US Standard Sensors-Fig1.jpg No edit summary current
- 12:3612:36, 7 September 2026 diff hist +12,293 N Ultrasonic Standard Sensors Created page with "{{Language_sel|LANG=ger|ARTIKEL=Ultraschall-Normal-Prüfköpfe}} {{PSM_Infobox}} <span style="font-size:1.2em;font-weight:bold;">Ultrasonic standard sensors</span> __FORCETOC__ ==Fundamentals== Ultrasonic standard sensors, also known as single-element vertical sensors or longitudinal wave sensors, essentially consist of a piezoelectric ceramic transducer that generates mechanical stress waves and thus longitudinal waves as a result..." current
- 12:3612:36, 7 September 2026 diff hist 0 N File:Stosswellen Pruefkoepfe-2.JPG No edit summary current
- 12:3612:36, 7 September 2026 diff hist 0 N File:Stosswellen Pruefkoepfe-1.JPG No edit summary current
- 12:3512:35, 7 September 2026 diff hist +11,585 N Ultrasonic Shock Wave Sensors Created page with "{{Language_sel|LANG=ger|ARTIKEL=Ultraschall-Stoßwellen-Prüfköpfe}} {{PSM_Infobox}} <span style="font-size:1.2em;font-weight:bold;">Ultrasonic shock wave sensors</span> __FORCETOC__ ==Criteria for the use of sensors== Conventionally used and distributed standard sensors are employed in many testing tasks where sufficient measurement resolution and accuracy are required for most of the components under investigation. Due to..." current
- 12:3512:35, 7 September 2026 diff hist 0 N File:Ultraschall Pruefkoepfe-1.JPG No edit summary current
- 12:3412:34, 7 September 2026 diff hist +7,698 N Ultrasonic Sensors Created page with "{{Language_sel|LANG=ger|ARTIKEL=Ultraschall-Prüfköpfe}} {{PSM_Infobox}} <span style="font-size:1.2em;font-weight:bold;">Ultrasonic sensors</span> __FORCETOC__ ==General information== Ultrasonic sensors, also known as ultrasonic transducers or probes, are used to generate and receive ultrasonic signals, primarily in non-destructive material testing and medical diagnostics. In conjunction with analogue or digital ultrasonic testing equ..." current
- 12:3412:34, 7 September 2026 diff hist −3 Ultrasonic Runtime Measurement No edit summary current
- 12:3212:32, 7 September 2026 diff hist 0 N File:Ultraschall-Gruppenstrahler-Pruefkoepfe-6.jpg No edit summary current
- 12:3212:32, 7 September 2026 diff hist 0 N File:Ultraschall-Gruppenstrahler-Pruefkoepfe-5.jpg No edit summary current
- 12:3212:32, 7 September 2026 diff hist 0 N File:Ultraschall-Gruppenstrahler-Pruefkoepfe-4.jpg No edit summary current
- 12:3212:32, 7 September 2026 diff hist 0 N File:US-PA-Sensors-3.jpg No edit summary current
- 12:3212:32, 7 September 2026 diff hist 0 N File:US-PA-Sensors-2.jpg No edit summary current
- 12:3212:32, 7 September 2026 diff hist 0 N File:Ultraschall-Gruppenstrahler-Pruefkoepfe-1.jpg No edit summary current
- 12:3112:31, 7 September 2026 diff hist −1 Ultrasonic Phased Array Sensors No edit summary current
- 12:2912:29, 7 September 2026 diff hist +12,301 N Ultrasonic Phased Array Sensors Created page with "{{Language_sel|LANG=ger|ARTIKEL=Ultraschall-Gruppenstrahler-Prüfköpfe}} {{PSM_Infobox}} <span style="font-size:1.2em;font-weight:bold;">Ultrasonic phased array sensors</span> __FORCETOC__ ==General remarks== The so-called phased array technique has been used in medical ultrasound diagnostics since around 1970 and is successfully used to visualise internal organs in addition to radiographic diagnostics or MRT (magnetic resonance tomograp..."
- 12:2912:29, 7 September 2026 diff hist 0 N File:US Modulation Fig4b.jpg No edit summary current
- 12:2912:29, 7 September 2026 diff hist 0 N File:US Modulation Fig4a.jpg No edit summary current
- 12:2912:29, 7 September 2026 diff hist 0 N File:US Modulation Fig3.jpg No edit summary current
- 12:2912:29, 7 September 2026 diff hist 0 N File:US Modulation Fig2.jpg No edit summary current
- 12:2812:28, 7 September 2026 diff hist 0 N File:US Modulation Fig1.jpg No edit summary current
- 12:2812:28, 7 September 2026 diff hist +5,328 N Ultrasonic Modulation Created page with "{{Language_sel|LANG=ger|ARTIKEL=Ultraschall-Modulation}} {{PSM_Infobox}} <span style="font-size:1.2em;font-weight:bold;">Ultrasonic signals, modulation</span> __FORCETOC__ ==General== Unlike signal transmission methods, the modulation of ultrasonic signals is passive in nature. It is caused by the acoustic excitation of material inhomogeneities (defects), which can then act as secondary sound generators. In addition, a suitable excitation signa..." current
- 12:2712:27, 7 September 2026 diff hist 0 N File:US Laser Excitation-Fig3.jpg No edit summary current
- 12:2712:27, 7 September 2026 diff hist 0 N File:US Laser Excitation-Fig2.jpg No edit summary current
- 12:2712:27, 7 September 2026 diff hist 0 N File:US Laser Excitation-Fig1.jpg No edit summary current
- 12:2712:27, 7 September 2026 diff hist +8,858 N Ultrasonic Laser Excitation Created page with "{{Language_sel|LANG=ger|ARTIKEL=Ultraschall-Laser-Anregung}} {{PSM_Infobox}} <span style="font-size:1.2em;font-weight:bold;">Ultrasonic laser excitation</span> __FORCETOC__ ==General== In non-destructive testing using ultrasound, longitudinal or transverse waves can be introduced into the test object using standard, angle or Ultrasonic Transmitte..." current
- 12:2612:26, 7 September 2026 diff hist 0 N File:US Tauchbad Pruefkoepfe-2.jpg No edit summary current
- 12:2612:26, 7 September 2026 diff hist 0 N File:US Tauchbad Pruefkoepfe-1.jpg No edit summary current
- 12:2512:25, 7 September 2026 diff hist +4,968 N Ultrasonic Immersion Bath Sensors Created page with "{{Language_sel|LANG=ger|ARTIKEL=Ultraschall-Tauchbad-Prüfköpfe}} {{PSM_Infobox}} <span style="font-size:1.2em;font-weight:bold;">Ultrasonic immersion bath sensors</span> __FORCETOC__ ==Schematic configuration== Immersion bath sensors are similar in design to vertical or standard sensors, although they are slightly longer than sensors for direct coupling. To ensure watertightness and optimum impedance matc..." current
- 12:2512:25, 7 September 2026 diff hist +1 Ultrasonic Immersion Bath Technique No edit summary current
- 12:2512:25, 7 September 2026 diff hist +616 Ultrasonic Direct Coupling No edit summary current
- 12:2412:24, 7 September 2026 diff hist 0 N File:US-Compsit-Sensors-2.jpg No edit summary current
- 12:2412:24, 7 September 2026 diff hist 0 N File:US-Compsit-Sensors-1.jpg No edit summary current
- 12:2412:24, 7 September 2026 diff hist +9,017 N Ultrasonic Composite Sensors Created page with "{{Language_sel|LANG=ger|ARTIKEL=Ultraschall-Composite-Prüfköpfe}} {{PSM_Infobox}} <span style="font-size:1.2em;font-weight:bold;">Ultrasonic composite sensors</span> __FORCETOC__ ==General== Ultrasonic sensors containing composite transducers are increasingly being used in testing practice when low acoustic impedance and high acoustic efficiency for thickness vibrations are required [1−4]. At the same time, such composite sensors have low cro..." current
- 12:2312:23, 7 September 2026 diff hist 0 N File:US Angle Beam Fig7.jpg No edit summary current
- 12:2312:23, 7 September 2026 diff hist 0 N File:US Angle Beam Fig6.jpg No edit summary current
- 12:2312:23, 7 September 2026 diff hist 0 N File:US Angle Beam Fig5.jpg No edit summary current
- 12:2312:23, 7 September 2026 diff hist 0 N File:Winkelpruefkoepfe-4.JPG No edit summary current