<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://en.wiki.polymerservice-merseburg.de/index.php?action=history&amp;feed=atom&amp;title=Bend_Test_%E2%80%93_Specimen_Preparation</id>
	<title>Bend Test – Specimen Preparation - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://en.wiki.polymerservice-merseburg.de/index.php?action=history&amp;feed=atom&amp;title=Bend_Test_%E2%80%93_Specimen_Preparation"/>
	<link rel="alternate" type="text/html" href="https://en.wiki.polymerservice-merseburg.de/index.php?title=Bend_Test_%E2%80%93_Specimen_Preparation&amp;action=history"/>
	<updated>2026-04-22T21:39:25Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.43.1</generator>
	<entry>
		<id>https://en.wiki.polymerservice-merseburg.de/index.php?title=Bend_Test_%E2%80%93_Specimen_Preparation&amp;diff=899&amp;oldid=prev</id>
		<title>Oluschinski at 06:41, 15 December 2025</title>
		<link rel="alternate" type="text/html" href="https://en.wiki.polymerservice-merseburg.de/index.php?title=Bend_Test_%E2%80%93_Specimen_Preparation&amp;diff=899&amp;oldid=prev"/>
		<updated>2025-12-15T06:41:28Z</updated>

		<summary type="html">&lt;p&gt;&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 08:41, 15 December 2025&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l45&quot;&gt;Line 45:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 45:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;When removing test specimens from plastic components, e.g. for a failure analysis, standardized test specimens with the dimensions 80 mm x 10 mm x specimen thickness in mm should also be removed, if possible. In this case, particular attention must be noted to the direction of removal with respect to the component geometry and the direction of injection, and the test specimens must be clearly marked (&amp;#039;&amp;#039;&amp;#039;Fig. 4&amp;#039;&amp;#039;&amp;#039;). As a rule, transversely curved test specimens, e.g. taken from pipe segments, should not be used or, if they have the same geometry, should only be evaluated from a comparative point of view, since only a point contact on the support can be realized here.&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;When removing test specimens from plastic components, e.g. for a failure analysis, standardized test specimens with the dimensions 80 mm x 10 mm x specimen thickness in mm should also be removed, if possible. In this case, particular attention must be noted to the direction of removal with respect to the component geometry and the direction of injection, and the test specimens must be clearly marked (&amp;#039;&amp;#039;&amp;#039;Fig. 4&amp;#039;&amp;#039;&amp;#039;). As a rule, transversely curved test specimens, e.g. taken from pipe segments, should not be used or, if they have the same geometry, should only be evaluated from a comparative point of view, since only a point contact on the support can be realized here.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[file:&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Bend_Test_Specimen_Preparation4&lt;/del&gt;.jpg]]&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[file:&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;biegeversuchpkentnahme4&lt;/ins&gt;.jpg]]&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;{|  &lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;{|  &lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|- valign=&amp;quot;top&amp;quot;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|- valign=&amp;quot;top&amp;quot;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l54&quot;&gt;Line 54:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 54:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Slight longitudinal curvatures of the test specimens are acceptable, since these can be taken into account in the calculation equations for the peripheral fibre strain and the flexural strength (&amp;#039;&amp;#039;&amp;#039;Fig. 5&amp;#039;&amp;#039;&amp;#039;).&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Slight longitudinal curvatures of the test specimens are acceptable, since these can be taken into account in the calculation equations for the peripheral fibre strain and the flexural strength (&amp;#039;&amp;#039;&amp;#039;Fig. 5&amp;#039;&amp;#039;&amp;#039;).&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[file:&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Bend_Test_Specimen_Preparation5&lt;/del&gt;.jpg]]&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[file:&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Bend Test Specimen Preparation5&lt;/ins&gt;.jpg]]&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;{|  &lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;{|  &lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|- valign=&amp;quot;top&amp;quot;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|- valign=&amp;quot;top&amp;quot;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>Oluschinski</name></author>
	</entry>
	<entry>
		<id>https://en.wiki.polymerservice-merseburg.de/index.php?title=Bend_Test_%E2%80%93_Specimen_Preparation&amp;diff=100&amp;oldid=prev</id>
		<title>Oluschinski: /* Bending test specimen made of plastic components */</title>
		<link rel="alternate" type="text/html" href="https://en.wiki.polymerservice-merseburg.de/index.php?title=Bend_Test_%E2%80%93_Specimen_Preparation&amp;diff=100&amp;oldid=prev"/>
		<updated>2025-11-28T13:18:28Z</updated>

		<summary type="html">&lt;p&gt;&lt;span class=&quot;autocomment&quot;&gt;Bending test specimen made of plastic components&lt;/span&gt;&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 15:18, 28 November 2025&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l45&quot;&gt;Line 45:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 45:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;When removing test specimens from plastic components, e.g. for a failure analysis, standardized test specimens with the dimensions 80 mm x 10 mm x specimen thickness in mm should also be removed, if possible. In this case, particular attention must be noted to the direction of removal with respect to the component geometry and the direction of injection, and the test specimens must be clearly marked (&amp;#039;&amp;#039;&amp;#039;Fig. 4&amp;#039;&amp;#039;&amp;#039;). As a rule, transversely curved test specimens, e.g. taken from pipe segments, should not be used or, if they have the same geometry, should only be evaluated from a comparative point of view, since only a point contact on the support can be realized here.&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;When removing test specimens from plastic components, e.g. for a failure analysis, standardized test specimens with the dimensions 80 mm x 10 mm x specimen thickness in mm should also be removed, if possible. In this case, particular attention must be noted to the direction of removal with respect to the component geometry and the direction of injection, and the test specimens must be clearly marked (&amp;#039;&amp;#039;&amp;#039;Fig. 4&amp;#039;&amp;#039;&amp;#039;). As a rule, transversely curved test specimens, e.g. taken from pipe segments, should not be used or, if they have the same geometry, should only be evaluated from a comparative point of view, since only a point contact on the support can be realized here.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[file:&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;biegeversuchpkentnahme4&lt;/del&gt;.jpg]]&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[file:&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Bend_Test_Specimen_Preparation4&lt;/ins&gt;.jpg]]&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;{|  &lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;{|  &lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|- valign=&amp;quot;top&amp;quot;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|- valign=&amp;quot;top&amp;quot;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l54&quot;&gt;Line 54:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 54:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Slight longitudinal curvatures of the test specimens are acceptable, since these can be taken into account in the calculation equations for the peripheral fibre strain and the flexural strength (&amp;#039;&amp;#039;&amp;#039;Fig. 5&amp;#039;&amp;#039;&amp;#039;).&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Slight longitudinal curvatures of the test specimens are acceptable, since these can be taken into account in the calculation equations for the peripheral fibre strain and the flexural strength (&amp;#039;&amp;#039;&amp;#039;Fig. 5&amp;#039;&amp;#039;&amp;#039;).&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[file:&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;biegeversuchpkentnahme5&lt;/del&gt;.jpg]]&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;[[file:&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Bend_Test_Specimen_Preparation5&lt;/ins&gt;.jpg]]&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;{|  &lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;{|  &lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|- valign=&amp;quot;top&amp;quot;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;|- valign=&amp;quot;top&amp;quot;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>Oluschinski</name></author>
	</entry>
	<entry>
		<id>https://en.wiki.polymerservice-merseburg.de/index.php?title=Bend_Test_%E2%80%93_Specimen_Preparation&amp;diff=99&amp;oldid=prev</id>
		<title>Oluschinski: Created page with &quot;{{Language_sel|LANG=ger|ARTIKEL=Biegeversuch Prüfkörperentnahme}} {{PSM_Infobox}} &lt;span style=&quot;font-size:1.2em;font-weight:bold;&quot;&gt;Bend test – Specimen preparation&lt;/span&gt; __FORCETOC__  ==Specimen shapes for bend testing==  For the three-point bend test on plastics, in accordance with the relevant standards of  bend testing of plastics [1–3], the test  specimen with dimensions 80 mm x 10 mm x 4 mm is preferably used. This test specimen ca...&quot;</title>
		<link rel="alternate" type="text/html" href="https://en.wiki.polymerservice-merseburg.de/index.php?title=Bend_Test_%E2%80%93_Specimen_Preparation&amp;diff=99&amp;oldid=prev"/>
		<updated>2025-11-28T13:16:03Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;{{Language_sel|LANG=ger|ARTIKEL=Biegeversuch Prüfkörperentnahme}} {{PSM_Infobox}} &amp;lt;span style=&amp;quot;font-size:1.2em;font-weight:bold;&amp;quot;&amp;gt;Bend test – Specimen preparation&amp;lt;/span&amp;gt; __FORCETOC__  ==Specimen shapes for bend testing==  For the three-point bend test on plastics, in accordance with the relevant standards of &lt;a href=&quot;/index.php/Bend_Test&quot; title=&quot;Bend Test&quot;&gt; bend testing&lt;/a&gt; of plastics [1–3], the test &lt;a href=&quot;/index.php/Specimen&quot; title=&quot;Specimen&quot;&gt; specimen&lt;/a&gt; with dimensions 80 mm x 10 mm x 4 mm is preferably used. This test specimen ca...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{{Language_sel|LANG=ger|ARTIKEL=Biegeversuch Prüfkörperentnahme}}&lt;br /&gt;
{{PSM_Infobox}}&lt;br /&gt;
&amp;lt;span style=&amp;quot;font-size:1.2em;font-weight:bold;&amp;quot;&amp;gt;Bend test – Specimen preparation&amp;lt;/span&amp;gt;&lt;br /&gt;
__FORCETOC__&lt;br /&gt;
&lt;br /&gt;
==Specimen shapes for bend testing==&lt;br /&gt;
&lt;br /&gt;
For the three-point bend test on plastics, in accordance with the relevant standards of [[Bend Test | bend testing]] of plastics [1–3], the test [[Specimen | specimen]] with dimensions 80 mm x 10 mm x 4 mm is preferably used. This test specimen can be manufactured directly by injection moulding or from the [[Multipurpose Test Specimen | multipurpose test specimen]] type 1A by cutting off the plane-parallel part (&amp;#039;&amp;#039;&amp;#039;Fig. 1&amp;#039;&amp;#039;&amp;#039;). The advantage of this type of specimen production is the comparability of the internal condition of the specimens with respect to residual stress and orientations.&lt;br /&gt;
&lt;br /&gt;
[[file:Bend Test Specimen Preparation1.jpg]]&lt;br /&gt;
{| &lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|width=&amp;quot;50px&amp;quot;|&amp;#039;&amp;#039;&amp;#039;Fig. 1&amp;#039;&amp;#039;&amp;#039;: &lt;br /&gt;
|width=&amp;quot;600px&amp;quot; |Preparation of specimen for the bend test from multi-purpose specimen type 1A&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
==Specimen shapes for bend testing==&lt;br /&gt;
&lt;br /&gt;
The test specimens used must not have any rounded corners or edges or [[Sink Mark | sink marks]] due to impermissibly high volume shrinkage. The presence of cracks, burrs or scratches as well as strong tendency to demould test specimen in injection moulding can cause additional problems that falsify the measurement results. In addition, the test specimens should not exhibit any torsion and must have surfaces that are perpendicular and plane-parallel to one another. According to the mostly used standard ISO 178 [3], the nominal thickness should be in the interval of 3 to 5 mm, preferably 4 mm, and then the test specimen width should be 10 mm. In the case of deviating specimen thicknesses, the specimen width must then be adjusted accordingly [3].&lt;br /&gt;
&lt;br /&gt;
In principle, it is also possible to produce the required test specimens by sawing and milling from extruded or calendered sheets, in which case the sheet thickness influences the geometry of the test specimens. In this case, the width &amp;#039;&amp;#039;b&amp;#039;&amp;#039; must also be adapted to the nominal thickness of the sheet. As a result, widths of up to 50 mm are technically possible. If filled materials with coarse fillers with regard to geometry are to be characterized, then width and thickness must also be varied to avoid impermissibly high stress peaks. Since such specimens, which are made from plates, usually have a high degree of anisotropy, in this case specimen removal must be carried out in the two main directions (longitudinal = L and transverse = W), with the test direction (perpendicular = N and parallel = P) also being variable (&amp;#039;&amp;#039;&amp;#039;Fig. 2&amp;#039;&amp;#039;&amp;#039;).&lt;br /&gt;
&lt;br /&gt;
[[file:Bend Test Specimen Preparation2.jpg]]&lt;br /&gt;
{| &lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|width=&amp;quot;50px&amp;quot;|&amp;#039;&amp;#039;&amp;#039;Fig. 2&amp;#039;&amp;#039;&amp;#039;: &lt;br /&gt;
|width=&amp;quot;600px&amp;quot; |Production of specimen for bend test from anisotrope plates&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
==Test specimens for long fiber reinforced thermoset materials==&lt;br /&gt;
&lt;br /&gt;
Particular problems arise when specimens are taken from long-fibre-reinforced, layered anisotropic thermoset-based plastics (laminates). Since only normal stress components in the longitudinal direction of the test [[Specimen | specimen]] are taken into account in the standard-compliant evaluation of the [[Bend Test | bending test]], premature failure occurs under identical test conditions as with the short-fibre-reinforced materials. The cause is the occurrence of interlaminar shear fractures with large-area delaminations caused by the transverse force shear component. To minimize the [[Bend Test – Shear Stress | shear stress]] component, the ratio of support length &amp;#039;&amp;#039;L&amp;#039;&amp;#039; to test specimen thickness &amp;#039;&amp;#039;h&amp;#039;&amp;#039; is increased from normally 16 to 20 to 25 for such materials.&lt;br /&gt;
&lt;br /&gt;
To characterize the properties in the longitudinal and transverse directions, the test specimens must also be taken in both main orientation directions (&amp;#039;&amp;#039;&amp;#039;Fig. 3&amp;#039;&amp;#039;&amp;#039;), with the specimen length being based on the specimen thickness and the required [[Support Distance | support span]] ratio. Since the position of the specimens in relation to the main orientation direction has a decisive influence on the characteristic [[Material Value | material value]] level, the prismatic specimens must be prepared from the laminated sheets as shown in &amp;#039;&amp;#039;&amp;#039;Figure 3&amp;#039;&amp;#039;&amp;#039;. In this case, the removal direction of the specimens must be clearly marked with respect to the processing or orientation direction [4].&lt;br /&gt;
&lt;br /&gt;
[[file:Bend Test Specimen Preparation3.jpg]]&lt;br /&gt;
{| &lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|width=&amp;quot;50px&amp;quot;|&amp;#039;&amp;#039;&amp;#039;Fig. 3&amp;#039;&amp;#039;&amp;#039;: &lt;br /&gt;
|width=&amp;quot;600px&amp;quot; |Position of specimen for the bend test at anisotrope materials (laminates)&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
==Bending test specimen made of plastic components==&lt;br /&gt;
&lt;br /&gt;
When removing test specimens from plastic components, e.g. for a failure analysis, standardized test specimens with the dimensions 80 mm x 10 mm x specimen thickness in mm should also be removed, if possible. In this case, particular attention must be noted to the direction of removal with respect to the component geometry and the direction of injection, and the test specimens must be clearly marked (&amp;#039;&amp;#039;&amp;#039;Fig. 4&amp;#039;&amp;#039;&amp;#039;). As a rule, transversely curved test specimens, e.g. taken from pipe segments, should not be used or, if they have the same geometry, should only be evaluated from a comparative point of view, since only a point contact on the support can be realized here.&lt;br /&gt;
&lt;br /&gt;
[[file:biegeversuchpkentnahme4.jpg]]&lt;br /&gt;
{| &lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|width=&amp;quot;50px&amp;quot;|&amp;#039;&amp;#039;&amp;#039;Fig. 4&amp;#039;&amp;#039;&amp;#039;: &lt;br /&gt;
|width=&amp;quot;600px&amp;quot; |Removal of specimen for the bend test from plastic components&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Slight longitudinal curvatures of the test specimens are acceptable, since these can be taken into account in the calculation equations for the peripheral fibre strain and the flexural strength (&amp;#039;&amp;#039;&amp;#039;Fig. 5&amp;#039;&amp;#039;&amp;#039;).&lt;br /&gt;
&lt;br /&gt;
[[file:biegeversuchpkentnahme5.jpg]]&lt;br /&gt;
{| &lt;br /&gt;
|- valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|width=&amp;quot;50px&amp;quot;|&amp;#039;&amp;#039;&amp;#039;Fig. 5&amp;#039;&amp;#039;&amp;#039;: &lt;br /&gt;
|width=&amp;quot;600px&amp;quot; |Curved test specimen for the bend test from plastic components&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
==See also==&lt;br /&gt;
&lt;br /&gt;
*[[Bend Test | Bend test]]&lt;br /&gt;
*[[Bend Test – Test Influences | Bend test – Test influences]]&lt;br /&gt;
*[[Bend Test – Shear Stress | Bend test – Shear stress]]&lt;br /&gt;
*[[Bend Loading | Bend loading]]&lt;br /&gt;
*[[Bend Test – Specimen Shapes | Bend test – Specimen shapes]]&lt;br /&gt;
*[[Bend Test – Yield Stress | Bend test – Yield stress]]&lt;br /&gt;
&lt;br /&gt;
&amp;#039;&amp;#039;&amp;#039;Referencex&amp;#039;&amp;#039;&amp;#039;&lt;br /&gt;
&lt;br /&gt;
{|&lt;br /&gt;
|-valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|[1]&lt;br /&gt;
|[[Bierögel,_Christian|Bierögel, C.]]: Bend Test on Polymers. In: [[Grellmann,_Wolfgang|Grellmann, W.]], [[Seidler,_Sabine|Seidler, S.]] (Eds.): Polymer Testing. Carl Hanser Munich (2022) 3. Edition, 133–143 (ISBN 978-1-56990-806-8; see under [[AMK-Büchersammlung|AMK-Library]] A 22)&lt;br /&gt;
|-valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|[2]&lt;br /&gt;
|Bierögel, C., [https://www.researchgate.net/profile/Wolfgang-Grellmann Grellmann, W.]: Bend Loading. In: [https://de.wikipedia.org/wiki/Wolfgang_Grellmann Grellmann, W.], [https://www.researchgate.net/profile/Sabine-Seidler Sabine Seidler] (Eds.): Mechanical and Thermomechanical Properties of Polymers. Landolt-Börnstein, Volume VIII/6A3, Springer Berlin (2014) 164–191, (ISBN 978-3-642-55165-9; see under [[AMK-Büchersammlung|AMK-Library]] A 16)&lt;br /&gt;
|-valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|[3]&lt;br /&gt;
|ISO 178 (2019-04): Plastics – Determination of Flexural Properties&lt;br /&gt;
|-valign=&amp;quot;top&amp;quot;&lt;br /&gt;
|[4]&lt;br /&gt;
|ISO 14125 (1998-03): Fibre-reinforced Plastic Composites – Determination of Flexural Properties, Technical Corrigendum Cor.1:2001-07 and Amd.1:2011-02&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
[[Category:Bend Test]]&lt;/div&gt;</summary>